RicaoraRicaora
CHARGING TIME AND COST

Bollore Bluesummer

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

1 version≈ 30 kWh in the catalogueSources for every version

Set up your charging session

Your version is selected. Choose where to charge.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
Bluesummer LMP 30 · 2015 · France · AC420 kWh6.00 €13.00 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Some capacities are indicative. Version notes distinguish documented values from estimates.

Bluesummer LMP 30 · 2015 · France · AC4LMP 30 · 2015 · Documented data with indicative values
Indicative usable capacity
≈ 30 kWh
Maximum AC power
4 kW
Maximum DC power
Unavailable
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Connectors
AC: Type 1 · DC: Non disponibile
Documented configuration
2015
Configuration market
France
Market status
Historical version

Source market: France. Historical configuration; current ordering availability is not certified.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Indicative usable capacity: value from the independent technical source, not manufacturer confirmation of net capacity. Declared 30 kWh LMP battery and AC 4 kW from the technical source; configuration without DC. LMP heating and thermal maintenance consume energy while parked; the fixed-loss calculation excludes this consumption. Compare with measured energy.

AC charging time from 20–80%

Energy stored in this window is approximately 18 kWh. With 10% losses, estimated supply energy is 20 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW8 h 42 min
3.7 kW3.7 kW5 h 25 min
7.4 kW4 kW5 h 00 min
11 kW4 kW5 h 00 min
22 kW4 kW5 h 00 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue does not list rapid DC charging for this version. It charges on AC up to 4 kW under conditions compatible with its onboard charger.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Bollore Bluesummer, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore