RicaoraRicaora
CHARGING TIME AND COST

Elaris Dyo

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

2 versions≈ 30 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
Dyo 30 MY2024 · 2024 · Germany · AC1120 kWh6.00 €13.00 €
Dyo 30 pre-MY2024 · 2023 · Germany · AC3.320 kWh6.00 €13.00 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Some capacities are indicative. Version notes distinguish documented values from estimates.

Dyo 30 MY2024 · 2024 · Germany · AC1130 MY2024 · 2024 · Documented data with indicative values
Indicative usable capacity
≈ 30 kWh
Maximum AC power
11 kW
Maximum DC power
20 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Connectors
AC: Type 2 · DC: CCS
Documented configuration
2024
Configuration market
Germany
Market status
Historical version

Source market: Germany. Historical configuration; current ordering availability is not certified.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Indicative usable capacity: the source states capacity without certifying it as net here; energy, time and cost may be overestimated. The manufacturer page distinguishes AC 3.3 and AC 11 kW from MY2024. Battery 30 kWh gross, not 31.8 kWh from other editions. No NEDC range is imported as WLTP.

AC charging time from 20–80%

Energy stored in this window is approximately 18 kWh. With 10% losses, estimated supply energy is 20 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW8 h 42 min
3.7 kW3.7 kW5 h 25 min
7.4 kW7.4 kW2 h 43 min
11 kW11 kW1 h 50 min
22 kW11 kW1 h 50 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue reports a reference of 30–80% in 60 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.

Sources and version

Dyo 30 pre-MY2024 · 2023 · Germany · AC3.330 pre-MY2024 · 2023 · Documented data with indicative values
Indicative usable capacity
≈ 30 kWh
Maximum AC power
3.3 kW
Maximum DC power
20 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Connectors
AC: Type 2 · DC: CCS
Documented configuration
2023
Configuration market
Germany
Market status
Historical version

Source market: Germany. Historical configuration; current ordering availability is not certified.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Indicative usable capacity: the source states capacity without certifying it as net here; energy, time and cost may be overestimated. The manufacturer page distinguishes AC 3.3 and AC 11 kW from MY2024. Battery 30 kWh gross, not 31.8 kWh from other editions. No NEDC range is imported as WLTP.

AC charging time from 20–80%

Energy stored in this window is approximately 18 kWh. With 10% losses, estimated supply energy is 20 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW8 h 42 min
3.7 kW3.3 kW6 h 04 min
7.4 kW3.3 kW6 h 04 min
11 kW3.3 kW6 h 04 min
22 kW3.3 kW6 h 04 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue reports a reference of 30–80% in 60 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Elaris Dyo, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore