RicaoraRicaora
CHARGING TIME AND COST

Genesis GV60

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

2 versions≈ 84 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
GV60 84 202656 kWh16.80 €36.40 €
GV60 MY27 8456 kWh16.80 €36.40 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Some capacities are indicative. Version notes distinguish documented values from estimates.

GV60 84 2026Restyling · NL · 2026 · 84 kWh dichiarati · Documented data with indicative values
Indicative usable capacity
≈ 84 kWh
Maximum AC power
11 kW
Maximum DC power
240 kW
Nominal/gross capacity
84 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Indicative usable capacity: the manufacturer publishes battery capacity without specifying net capacity.

AC charging time from 20–80%

Energy stored in this window is approximately 50.4 kWh. With 10% losses, estimated supply energy is 56 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW24 h 21 min
3.7 kW3.7 kW15 h 09 min
7.4 kW7.4 kW7 h 35 min
11 kW11 kW5 h 06 min
22 kW11 kW5 h 06 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue reports a reference of 10–80% in 18 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.

Sources and version

GV60 MY27 84Europe · MY2027 · 84 kWh dichiarati · Documented data with indicative values
Indicative usable capacity
≈ 84 kWh
Maximum AC power
11 kW
Maximum DC power
240 kW
Nominal/gross capacity
84 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

The source states battery capacity without specifying net capacity. The rated figure is used as an approximation and may overestimate usable energy.

AC charging time from 20–80%

Energy stored in this window is approximately 50.4 kWh. With 10% losses, estimated supply energy is 56 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW24 h 21 min
3.7 kW3.7 kW15 h 09 min
7.4 kW7.4 kW7 h 35 min
11 kW11 kW5 h 06 min
22 kW11 kW5 h 06 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue reports a reference of 10–80% in 18 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Genesis GV60, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore