RicaoraRicaora
CHARGING TIME AND COST

Renault Megane E-Tech

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

4 versions40–60 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
Megane E-Tech40 kWh12.00 €26.00 €
Megane E-Tech 40 Boost26.67 kWh8.00 €17.33 €
Megane E-Tech 40 Standard26.67 kWh8.00 €17.33 €
Megane E-Tech 60 Super40 kWh12.00 €26.00 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Megane E-TechEV60 · 220 CV · Optimum Charge · range Italy 2022 · Manufacturer-documented specifications
Usable battery capacity
60 kWh
Maximum AC power
22 kW
Maximum DC power
130 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 36 kWh. With 10% losses, estimated supply energy is 40 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW17 h 24 min
3.7 kW3.7 kW10 h 49 min
7.4 kW7.4 kW5 h 25 min
11 kW11 kW3 h 39 min
22 kW22 kW1 h 50 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

Megane E-Tech 40 BoostEV40 · 130 CV · Boost Charge · range Italy 2022 · Manufacturer-documented specifications
Usable battery capacity
40 kWh
Maximum AC power
22 kW
Maximum DC power
85 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 24 kWh. With 10% losses, estimated supply energy is 26.7 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW11 h 36 min
3.7 kW3.7 kW7 h 13 min
7.4 kW7.4 kW3 h 37 min
11 kW11 kW2 h 26 min
22 kW22 kW1 h 13 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

Megane E-Tech 40 StandardFR · 2022 · EV40 standard charge · Manufacturer-documented specifications
Usable battery capacity
40 kWh
Maximum AC power
7.4 kW
Maximum DC power
Unavailable
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 24 kWh. With 10% losses, estimated supply energy is 26.7 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW11 h 36 min
3.7 kW3.7 kW7 h 13 min
7.4 kW7.4 kW3 h 37 min
11 kW7.4 kW3 h 37 min
22 kW7.4 kW3 h 37 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue does not list rapid DC charging for this version. It charges on AC up to 7.4 kW under conditions compatible with its onboard charger.

Sources and version

Megane E-Tech 60 SuperFR · 2022 · EV60 super charge · Manufacturer-documented specifications
Usable battery capacity
60 kWh
Maximum AC power
7.4 kW
Maximum DC power
130 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 36 kWh. With 10% losses, estimated supply energy is 40 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW17 h 24 min
3.7 kW3.7 kW10 h 49 min
7.4 kW7.4 kW5 h 25 min
11 kW7.4 kW5 h 25 min
22 kW7.4 kW5 h 25 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Renault Megane E-Tech, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore