RicaoraRicaora
CHARGING TIME AND COST

Skywell BE11

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

2 versions≈ 68–81 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
BE11 Long Range 2024 · 2024 · Europe · AC1154 kWh16.20 €35.10 €
BE11 Standard Range 2024 · 2024 · Europe · AC1145.33 kWh13.60 €29.47 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Some capacities are indicative. Version notes distinguish documented values from estimates.

BE11 Long Range 2024 · 2024 · Europe · AC11Long Range 2024 · 2024 · Documented data with indicative values
Indicative usable capacity
≈ 81 kWh
Maximum AC power
11 kW
Maximum DC power
80 kW
Nominal/gross capacity
86 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Connectors
AC: Type 2 · DC: CCS
Documented configuration
2024
Configuration market
Europe
Market status
Historical version

Source market: Europe. Historical configuration; current ordering availability is not certified.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Indicative usable capacity: value from the independent technical source, not manufacturer confirmation of net capacity. Battery and limits describe the European specification in the independent source; they do not certify every model year or national equipment level.

AC charging time from 20–80%

Energy stored in this window is approximately 48.6 kWh. With 10% losses, estimated supply energy is 54 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW23 h 29 min
3.7 kW3.7 kW14 h 36 min
7.4 kW7.4 kW7 h 18 min
11 kW11 kW4 h 55 min
22 kW11 kW4 h 55 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

BE11 Standard Range 2024 · 2024 · Europe · AC11Standard Range 2024 · 2024 · Documented data with indicative values
Indicative usable capacity
≈ 68 kWh
Maximum AC power
11 kW
Maximum DC power
80 kW
Nominal/gross capacity
72 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Connectors
AC: Type 2 · DC: CCS
Documented configuration
2024
Configuration market
Europe
Market status
Historical version

Source market: Europe. Historical configuration; current ordering availability is not certified.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Indicative usable capacity: value from the independent technical source, not manufacturer confirmation of net capacity. Battery and limits describe the European specification in the independent source; they do not certify every model year or national equipment level.

AC charging time from 20–80%

Energy stored in this window is approximately 40.8 kWh. With 10% losses, estimated supply energy is 45.3 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW19 h 43 min
3.7 kW3.7 kW12 h 16 min
7.4 kW7.4 kW6 h 08 min
11 kW11 kW4 h 08 min
22 kW11 kW4 h 08 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Skywell BE11, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore