RicaoraRicaora
CHARGING TIME AND COST

MG MG4 Urban

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

3 versions41.9–52.8 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
MG4 Urban Comfort43 41.9 net AC11 Europe 202627.93 kWh8.38 €18.16 €
MG4 Urban Comfort54 52.8 net AC11 Europe 202635.2 kWh10.56 €22.88 €
MG4 Urban Premium54 52.8 net AC11 Europe 202635.2 kWh10.56 €22.88 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

MG4 Urban Comfort43 41.9 net AC11 Europe 2026MG4 Urban Comfort43 41.9 net AC11 Europe 2026 · 2026 · Manufacturer-documented specifications
Usable battery capacity
41.9 kWh
Maximum AC power
11 kW
Maximum DC power
82 kW
Nominal/gross capacity
42.8 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Motor and drivetrain
110 kW ·
Documented configuration
2026
Market status
Model marketed in Italy

Source configuration and market are identified; check your vehicle year and equipment.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Finnish sheet dated 26 May 2026 explicitly distinguishes net/gross 41.9/42.8 and 52.8/53.9 kWh. The 49 kWh heading typo is not a third battery; the 150 kW test station is not assigned as vehicle power.

AC charging time from 20–80%

Energy stored in this window is approximately 25.1 kWh. With 10% losses, estimated supply energy is 27.9 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW12 h 09 min
3.7 kW3.7 kW7 h 33 min
7.4 kW7.4 kW3 h 47 min
11 kW11 kW2 h 33 min
22 kW11 kW2 h 33 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

MG4 Urban Comfort54 52.8 net AC11 Europe 2026MG4 Urban Comfort54 52.8 net AC11 Europe 2026 · 2026 · Manufacturer-documented specifications
Usable battery capacity
52.8 kWh
Maximum AC power
11 kW
Maximum DC power
87 kW
Nominal/gross capacity
53.9 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Motor and drivetrain
118 kW ·
Documented configuration
2026
Market status
Model marketed in Italy

Source configuration and market are identified; check your vehicle year and equipment.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Finnish sheet dated 26 May 2026 explicitly distinguishes net/gross 41.9/42.8 and 52.8/53.9 kWh. The 49 kWh heading typo is not a third battery; the 150 kW test station is not assigned as vehicle power.

AC charging time from 20–80%

Energy stored in this window is approximately 31.7 kWh. With 10% losses, estimated supply energy is 35.2 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW15 h 19 min
3.7 kW3.7 kW9 h 31 min
7.4 kW7.4 kW4 h 46 min
11 kW11 kW3 h 12 min
22 kW11 kW3 h 12 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

MG4 Urban Premium54 52.8 net AC11 Europe 2026MG4 Urban Premium54 52.8 net AC11 Europe 2026 · 2026 · Manufacturer-documented specifications
Usable battery capacity
52.8 kWh
Maximum AC power
11 kW
Maximum DC power
87 kW
Nominal/gross capacity
53.9 kWh
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Motor and drivetrain
118 kW ·
Documented configuration
2026
Market status
Model marketed in Italy

Source configuration and market are identified; check your vehicle year and equipment.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

Finnish sheet dated 26 May 2026 explicitly distinguishes net/gross 41.9/42.8 and 52.8/53.9 kWh. The 49 kWh heading typo is not a third battery; the 150 kW test station is not assigned as vehicle power.

AC charging time from 20–80%

Energy stored in this window is approximately 31.7 kWh. With 10% losses, estimated supply energy is 35.2 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW15 h 19 min
3.7 kW3.7 kW9 h 31 min
7.4 kW7.4 kW4 h 46 min
11 kW11 kW3 h 12 min
22 kW11 kW3 h 12 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For MG MG4 Urban, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore