Nio ET7
Choose your version and where to charge. Then calculate charging time and cost with your car already selected.
Set up your charging session
How much does charging cost?
Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.
Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.
Example from 20–80%, with assumed losses of 10%.
| Version | Estimated supply energy | Home | Public |
|---|---|---|---|
| ET7 100kWh | 66.67 kWh | 20.00 € | 43.33 € |
| ET7 100kWh DC125 | 66.67 kWh | 20.00 € | 43.33 € |
| ET7 75kWh | 50 kWh | 15.00 € | 32.50 € |
Technical data and sources Versions, AC tables and DC references
Versions and technical data
Check your version's year and equipment. Specifications, indicative tables and sources are listed here.
Some capacities are indicative. Version notes distinguish documented values from estimates.
ET7 100kWhET7 · NL · 2023 · 100 kWh dichiarati · batteria DC180 · Documented data with indicative values
- Indicative usable capacity
- ≈ 100 kWh
- Maximum AC power
- 11 kW
- Maximum DC power
- 180 kW
- Nominal/gross capacity
- 100 kWh
- Declared WLTP range
- Not verified in the catalogue
- Declared WLTP consumption
- Not verified in the catalogue
- Market status
- Check availability in your country
Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.
Declared capacity: net capacity is unspecified. BaaS may supply packs with different DC limits; choose the pack actually installed.
AC charging time from 20–80%
Energy stored in this window is approximately 60 kWh. With 10% losses, estimated supply energy is 66.7 kWh.
| Available power | Applied limit | Estimated time |
|---|---|---|
| 2.3 kW | 2.3 kW | 29 h 00 min |
| 3.7 kW | 3.7 kW | 18 h 02 min |
| 7.4 kW | 7.4 kW | 9 h 01 min |
| 11 kW | 11 kW | 6 h 04 min |
| 22 kW | 11 kW | 6 h 04 min |
Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.
Rapid DC charging
The catalogue reports a reference of 10–80% in 30 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.
Sources and version
- Primary source (original title): Nio · fonte costruttore ↗
- Verification date in the catalogue: . Check your car's year, market and equipment in the source.
ET7 100kWh DC125ET7 · NL · 2023 · 100 kWh dichiarati · batteria DC125 · Documented data with indicative values
- Indicative usable capacity
- ≈ 100 kWh
- Maximum AC power
- 11 kW
- Maximum DC power
- 125 kW
- Nominal/gross capacity
- 100 kWh
- Declared WLTP range
- Not verified in the catalogue
- Declared WLTP consumption
- Not verified in the catalogue
- Market status
- Check availability in your country
Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.
Declared capacity: net capacity is unspecified. BaaS may supply packs with different DC limits; choose the pack actually installed.
AC charging time from 20–80%
Energy stored in this window is approximately 60 kWh. With 10% losses, estimated supply energy is 66.7 kWh.
| Available power | Applied limit | Estimated time |
|---|---|---|
| 2.3 kW | 2.3 kW | 29 h 00 min |
| 3.7 kW | 3.7 kW | 18 h 02 min |
| 7.4 kW | 7.4 kW | 9 h 01 min |
| 11 kW | 11 kW | 6 h 04 min |
| 22 kW | 11 kW | 6 h 04 min |
Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.
Rapid DC charging
The catalogue reports a reference of 10–80% in 40 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.
Sources and version
- Primary source (original title): Nio · fonte costruttore ↗
- Verification date in the catalogue: . Check your car's year, market and equipment in the source.
ET7 75kWhET7 · NL · 2023 · 75 kWh dichiarati · batteria DC140 · Documented data with indicative values
- Indicative usable capacity
- ≈ 75 kWh
- Maximum AC power
- 11 kW
- Maximum DC power
- 140 kW
- Nominal/gross capacity
- 75 kWh
- Declared WLTP range
- Not verified in the catalogue
- Declared WLTP consumption
- Not verified in the catalogue
- Market status
- Check availability in your country
Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.
Declared capacity: net capacity is unspecified. BaaS may supply packs with different DC limits; choose the pack actually installed.
AC charging time from 20–80%
Energy stored in this window is approximately 45 kWh. With 10% losses, estimated supply energy is 50 kWh.
| Available power | Applied limit | Estimated time |
|---|---|---|
| 2.3 kW | 2.3 kW | 21 h 45 min |
| 3.7 kW | 3.7 kW | 13 h 31 min |
| 7.4 kW | 7.4 kW | 6 h 46 min |
| 11 kW | 11 kW | 4 h 33 min |
| 22 kW | 11 kW | 4 h 33 min |
Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.
Rapid DC charging
The catalogue reports a reference of 10–80% in 30 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.
Sources and version
- Primary source (original title): Nio · fonte costruttore ↗
- Verification date in the catalogue: . Check your car's year, market and equipment in the source.
How to use these results
A 22 kW AC station cannot exceed the onboard charger limit. For Nio ET7, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.
Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.