RicaoraRicaora
CHARGING TIME AND COST

Renault Twingo E-Tech

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

3 versions22–27.5 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
Twingo E-Tech 22 202014.67 kWh4.40 €9.53 €
Twingo E-Tech 27.5 202618.33 kWh5.50 €11.92 €
Twingo E-Tech 27.5 Advanced Charge18.33 kWh5.50 €11.92 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Twingo E-Tech 22 2020Twingo III · 2020–2024 · AC only · Manufacturer-documented specifications
Usable battery capacity
22 kWh
Maximum AC power
22 kW
Maximum DC power
Unavailable
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 13.2 kWh. With 10% losses, estimated supply energy is 14.7 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW6 h 23 min
3.7 kW3.7 kW3 h 58 min
7.4 kW7.4 kW1 h 59 min
11 kW11 kW1 h 20 min
22 kW22 kW40 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue does not list rapid DC charging for this version. It charges on AC up to 22 kW under conditions compatible with its onboard charger.

Sources and version

Twingo E-Tech 27.5 2026FR · 2026 · senza Advanced Charge · Manufacturer-documented specifications
Usable battery capacity
27.5 kWh
Maximum AC power
6.6 kW
Maximum DC power
Unavailable
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 16.5 kWh. With 10% losses, estimated supply energy is 18.3 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW7 h 59 min
3.7 kW3.7 kW4 h 58 min
7.4 kW6.6 kW2 h 47 min
11 kW6.6 kW2 h 47 min
22 kW6.6 kW2 h 47 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue does not list rapid DC charging for this version. It charges on AC up to 6.6 kW under conditions compatible with its onboard charger.

Sources and version

Twingo E-Tech 27.5 Advanced ChargeFR · 2026 · Advanced Charge · Manufacturer-documented specifications
Usable battery capacity
27.5 kWh
Maximum AC power
11 kW
Maximum DC power
50 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 16.5 kWh. With 10% losses, estimated supply energy is 18.3 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW7 h 59 min
3.7 kW3.7 kW4 h 58 min
7.4 kW7.4 kW2 h 29 min
11 kW11 kW1 h 40 min
22 kW11 kW1 h 40 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Renault Twingo E-Tech, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore