RicaoraRicaora
CHARGING TIME AND COST

Volkswagen ID.3

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

7 versions45–79 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
ID.3 5838.67 kWh11.60 €25.13 €
ID.3 7751.33 kWh15.40 €33.37 €
ID.3 GTX 202452.67 kWh15.80 €34.23 €
ID.3 Pro 202439.33 kWh11.80 €25.57 €
ID.3 Pure 202130 kWh9.00 €19.50 €
ID.3 Pure 2021 DC5030 kWh9.00 €19.50 €
ID.3 Pure 202434.67 kWh10.40 €22.53 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

ID.3 58Pro Performance · Europe · launch 2020 · Manufacturer-documented specifications
Usable battery capacity
58 kWh
Maximum AC power
11 kW
Maximum DC power
100 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 34.8 kWh. With 10% losses, estimated supply energy is 38.7 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW16 h 49 min
3.7 kW3.7 kW10 h 28 min
7.4 kW7.4 kW5 h 14 min
11 kW11 kW3 h 31 min
22 kW11 kW3 h 31 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

ID.3 77Pro S · Europe · MY24 · Manufacturer-documented specifications
Usable battery capacity
77 kWh
Maximum AC power
11 kW
Maximum DC power
175 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 46.2 kWh. With 10% losses, estimated supply energy is 51.3 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW22 h 20 min
3.7 kW3.7 kW13 h 53 min
7.4 kW7.4 kW6 h 57 min
11 kW11 kW4 h 40 min
22 kW11 kW4 h 40 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

ID.3 GTX 2024GTX 2024 · Europe · MY24 · Manufacturer-documented specifications
Usable battery capacity
79 kWh
Maximum AC power
11 kW
Maximum DC power
185 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 47.4 kWh. With 10% losses, estimated supply energy is 52.7 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW22 h 54 min
3.7 kW3.7 kW14 h 15 min
7.4 kW7.4 kW7 h 08 min
11 kW11 kW4 h 48 min
22 kW11 kW4 h 48 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

ID.3 Pro 2024Pro 2024 · Europe · MY24 · Manufacturer-documented specifications
Usable battery capacity
59 kWh
Maximum AC power
11 kW
Maximum DC power
165 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 35.4 kWh. With 10% losses, estimated supply energy is 39.3 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW17 h 07 min
3.7 kW3.7 kW10 h 38 min
7.4 kW7.4 kW5 h 19 min
11 kW11 kW3 h 35 min
22 kW11 kW3 h 35 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

ID.3 Pure 2021Pure Performance · Europe · 2021 · DC100 optional · Manufacturer-documented specifications
Usable battery capacity
45 kWh
Maximum AC power
7.2 kW
Maximum DC power
100 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 27 kWh. With 10% losses, estimated supply energy is 30 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW13 h 03 min
3.7 kW3.7 kW8 h 07 min
7.4 kW7.2 kW4 h 10 min
11 kW7.2 kW4 h 10 min
22 kW7.2 kW4 h 10 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

ID.3 Pure 2021 DC50Pure Performance · Europe · 2021 · DC50 standard · Manufacturer-documented specifications
Usable battery capacity
45 kWh
Maximum AC power
7.2 kW
Maximum DC power
50 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 27 kWh. With 10% losses, estimated supply energy is 30 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW13 h 03 min
3.7 kW3.7 kW8 h 07 min
7.4 kW7.2 kW4 h 10 min
11 kW7.2 kW4 h 10 min
22 kW7.2 kW4 h 10 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

ID.3 Pure 2024Pure 2024 · Europe · MY24 · Manufacturer-documented specifications
Usable battery capacity
52 kWh
Maximum AC power
11 kW
Maximum DC power
145 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Not verified in the catalogue
Declared WLTP consumption
Not verified in the catalogue
Market status
Check availability in your country

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

AC charging time from 20–80%

Energy stored in this window is approximately 31.2 kWh. With 10% losses, estimated supply energy is 34.7 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW15 h 05 min
3.7 kW3.7 kW9 h 23 min
7.4 kW7.4 kW4 h 42 min
11 kW11 kW3 h 10 min
22 kW11 kW3 h 10 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

No DC time reference with a battery window is reported for this version. Peak kW cannot establish actual time: power varies with battery, temperature and station. The full calculator uses an estimated curve and explains its limits.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Volkswagen ID.3, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore