RicaoraRicaora
CHARGING TIME AND COST

Lynk & Co 02

Choose your version and where to charge. Then calculate charging time and cost with your car already selected.

2 versions≈ 66 kWh in the catalogueSources for every version

Set up your charging session

Choose a version to see its charging limits and continue.

In the calculator you can change percentages, power, tariff and conditions. For a household socket, ask a qualified professional to check that the installation is suitable for EV charging.

How much does charging cost?

Compare batteries using your tariffs. Initial values of 0.30 and 0.65 €/kWh are examples, not offers or market averages.

Supply energy = usable capacity × charge change ÷ (1 − losses). Costs cover energy only, excluding subscriptions and other charges. Actual losses vary with power, installation and temperature.

Example from 20–80%, with assumed losses of 10%.

Session energy and cost for each battery
VersionEstimated supply energyHomePublic
02 Core 66 AC11 202644 kWh13.20 €28.60 €
02 More 66 AC22 MY2744 kWh13.20 €28.60 €
Technical data and sources Versions, AC tables and DC references

Versions and technical data

Check your version's year and equipment. Specifications, indicative tables and sources are listed here.

Some capacities are indicative. Version notes distinguish documented values from estimates.

02 Core 66 AC11 2026Core · AC11 · Italyn range consulted in 2026 · Documented data with indicative values
Indicative usable capacity
≈ 66 kWh
Maximum AC power
11 kW
Maximum DC power
150 kW
Nominal/gross capacity
Unverified
Declared WLTP range
Up to 435 km
Declared WLTP consumption
Not verified in the catalogue
Documented configuration
2026
Market status
Model marketed in Italy

Model in the Italian range. Specifications refer to the indicated configuration and year; check your car equipment.

Internal calculator estimates are not shown as WLTP consumption or range. These data will be added after the exact version is verified.

The official Italian table distinguishes Core AC 11 and More AC 22 kW. EVKX gives 66 kWh usable, indicative because the manufacturer does not explicitly confirm it as net. Gross capacity and Core consumption are not imported; More MY27 consumption of 17.1 is not transferred. The 02 range page states 10–80% in 30 minutes.

AC charging time from 20–80%

Energy stored in this window is approximately 39.6 kWh. With 10% losses, estimated supply energy is 44 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW19 h 08 min
3.7 kW3.7 kW11 h 54 min
7.4 kW7.4 kW5 h 57 min
11 kW11 kW4 h 00 min
22 kW11 kW4 h 00 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue reports a reference of 10–80% in 30 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.

Sources and version

02 More 66 AC22 MY27Italy · 2027 · documented configuration · Documented data with indicative values
Indicative usable capacity
≈ 66 kWh
Maximum AC power
22 kW
Maximum DC power
150 kW
Nominal/gross capacity
Unverified
Declared WLTP range
445 km
Declared WLTP consumption
17.1 kWh/100 km
Motor and drivetrain
200 kW · Rear
Documented configuration
2027
Market status
Model marketed in Italy

Model in the Italian range. Specifications refer to the indicated configuration and year; check your car equipment.

Declared AC WLTP consumption includes charging energy: do not add losses again. It is a homologation value, not a prediction of road consumption.

Italian MY27 More sheet: declared battery 66 kWh (source unit typo: kW instead of kWh), AC 22/DC 150 kW, 10–80% in 30 minutes. EVKX documents 66 kWh usable; the manufacturer does not explicitly identify it as net, so capacity is indicative. Gross capacity is not imported from the independent source. WLTP consumption of 17.1 refers to More and is not transferred to Core AC 11.

AC charging time from 20–80%

Energy stored in this window is approximately 39.6 kWh. With 10% losses, estimated supply energy is 44 kWh.

Available powerApplied limitEstimated time
2.3 kW2.3 kW19 h 08 min
3.7 kW3.7 kW11 h 54 min
7.4 kW7.4 kW5 h 57 min
11 kW11 kW4 h 00 min
22 kW22 kW2 h 00 min

Simplified estimate: stored energy ÷ 0.90 ÷ effective power. Power is the lower of available power and the version's AC limit. Constant power is assumed: installation, phases, temperature and battery management can extend time. Listed powers are calculation scenarios, not an installation assessment.

Rapid DC charging

The catalogue reports a reference of 10–80% in 30 minutes. This reference applies to the stated version and source conditions; it is not a guaranteed time for every session. The full calculator uses it as a reference for the estimated curve.

Sources and version

How to use these results

A 22 kW AC station cannot exceed the onboard charger limit. For Lynk & Co 02, the individual version figures in the table are more useful than the commercial name alone. Also check available power and installation phases.

Estimated cost multiplies supply kWh by your tariff. DC charging follows a curve and cannot be calculated by dividing energy by peak power. Sources and reference windows are listed for each version.

Other models to explore